The R8 product line was recently upgraded with the following notable features:
- Flexible SIRIUS amplifiers, interfacing to virtually any kind of signal (quarter, half or full bridge strain gauges, accelerometers, pressure sensors, potentiometers, high voltage sources etc.).
- Low input-to-EtherCAT bus delay (< 100 us) when accessed by a third party EtherCAT master through the back panel EtherCAT port, with the minimum cycle time of 200 us. Even lower delay and cycle times are possible – please contact DEWESoft® support when this is required.
- A possibility of running the SIRIUSre slices in dual mode: full data rate over USB to Dewesoft® (not real-time, for analysis purposes) – and real-time data (for control purposes) to third party master through the backside EtherCAT port in parallel at the same time.
TESTING IN ALL THREE PERPENDICULAR AXIS 10 MIN EACH
EUT Test level Result R8R 10 min in each direction PASS, in-house test Direction Observation Result x-axis No influence on measurement results. PASS y-axis No influence on measurement results. PASS z-axis No influence on measurement results. PASS
For further information in Australia & New Zealand, please contact Metromatics on +61 7 3868 4255 or sales@metromatics.com.au
For outside this area, please contact DEWESoft directly sales@dewesoft.com
No comments: